How much damp proof membrane do I need?

Damp proof membrane (DPM) is measured by area and typically sold in rolls 4 m wide by 25 m long. To calculate the quantity needed, add the floor area plus 150-300 mm laps at all wall edges and 300 mm overlaps at sheet joints. Our calculator handles floors, walls, and gas membranes, includes lap and overlap allowances, and tells you exactly how many rolls to order for your project.

Damp Proof Membrane Calculator

Floor DPM, cavity drainage, tanking slurry and radon barrier - with upstands and tape

The membrane is turned up the wall - typically 150-300 mm. Set to 0 to ignore upstands.
50 m rolls - for sealing joints and upstand perimeter
10%
10% for regular rooms; 15-20% for awkward shapes or many internal corners.

Floor Areas

Job Costing (optional)

Rate x total area
Pro featurePopulate cost fields with current UK market prices. Sign in or upgrade to access.

Results

Rolls to Buy
-
rolls
Floor Area
-
Total inc. Upstands
-

Area Breakdown

🚫 Estimate waste & skip size for this project →

Doing this as a homeowner?
Who do you actually need to hire for this?
Who do I need?
Not sure what some of these terms mean?
Browse all →
Damp Proof Membrane Damp Proof Course Rising Damp Penetrating Damp Tanking Structural Waterproofing Type A Waterproofing Cavity Drain Membrane Hygroscopic Salts Condensation Interstitial Condensation Vapour Barrier Oversite Blinding Ground Bearing Slab Sump Screed Hardcore Efflorescence Foundation

Frequently Asked Questions

What thickness of damp proof membrane do I need?
Standard ground-bearing floor: 1200 gauge (300 micron) polyethylene sheet - the minimum under Approved Document C. Gas-resistant membranes (radon/methane protection): 300 or 450 micron with fully gas-tight sealed laps. Basement/high water table: a standard polythene DPM is not sufficient - use a cavity drain membrane or tanked waterproofing system.
Where does the damp proof membrane go in a floor construction?
Below the slab (sandwich DPM): laid on compacted hardcore/blinding sand before concrete is poured - most common position. Above the slab (surface DPM): laid on hardened concrete before screed or floor finish - must link to the wall DPC. All laps must be at least 150 mm and taped or welded to form a continuous barrier.
How much overlap do I need at DPM sheet joints?
Approved Document C: minimum 150 mm overlap at all sheet joints, taped with polythene or butyl tape to form a continuous barrier. Wall upstand: turn up 150-300 mm above finished floor level and connect to the wall DPC. All pipe penetrations: seal with proprietary sealing collars or tape to maintain continuity.
What is a radon barrier and when do I need one?
Radon is a radioactive gas that seeps from certain rocks and soils. In Basic Protection areas: a 300 micron membrane with sealed laps as the DPM is sufficient. In Full Protection areas: a radon sump and fan system must also be installed. Check your site on the UKHSA postcode radon checker or BRE Report BR 211 Affected Areas mapping.
What is a gas membrane and when is it required?
Required where a site is at risk from ground gases (methane, CO², radon) - typically brownfield sites, land near landfill, coal mining areas, or made ground. Gas membranes are 300-450 micron polyethylene or specialist multi-layer membranes with all laps welded or taped gas-tight. Risk identified via Phase 1 desk study and Phase 2 site investigation; protection measures must be designed by a suitably qualified engineer.
How do I calculate how many rolls of DPM I need?
DPM rolls are typically 4 m wide x 25 m long (100 m² per roll). Add floor area + wall upstand area (perimeter x upstand height, typically 0.15-0.3 m) + 10-15% for laps and waste. Example: 10 x 8 m floor: 80 m² floor + 7.2 m² upstands x 1.12 = 97.6 m² - one 100 m² roll covers it. For multiple sheets, count sheet widths and add 150 mm per lap.